D. F. Welch wrote: > All this is true except You MUST properly phase the windings you > connect in series or parallel. If you fail to do this properly the > fields will be bucking each other, the output low and the transformer > will get quite hot. Hang on! For secondaries in series, the first two will be true but the third does not follow. Think on it. -- Cheers, Paul B.