Douglas Reid wrote: Try TECCOR triacs instead. Had more than 10 times the failure rate with BTA's on 8x8 (64 triacs per card) lamp driver modules. The T4000 series is a much better triac for the same ratings in our experiences.. Alan > In fact, the Mk I version of this design used MOC3021 opto-triac drivers > driving > BTA06 600BW triacs. A snubber network using two resistors (360R and 470R) > plus a 50nF/ 400V cap was used between the driver and the triac. This was > used in the first of our 3 installations and whilst it worked well for a > time, was subject to catastrophic failure. On two occasions triacs failed > (in fact, as I recall, all 4 triacs on the card > were found to have failed). It had been considered that the triacs were > adequately specified - clearly, transient effects were not properly > considered! Given that we needed the system working quickly, we