Craig Niederberger wrote: > > Hi All, > > I just picked up the melabs picbasic compiler, and to my dismay found that > SERIN/SEROUT is implemented *only* on port B. In my app, I need > SERIN/SEROUT on port A. I emailed melabs, and they claimed that users > have successfully rewritten PBL.INC for port A SERIN/SEROUT. Anybody out > there have such a PBL.INC, or know of someone who might? Doesn't sound like they we very helpful was that your Impresion ? I have played with a couple of the commands (timeout on the serin and pause 1 = 100us not 1ms),but not what you want to do. However I am fairly certain that in your case you should be changing the pbh.inc and not the pbl.inc could you send me a copy of their email to you (to me and not the list) peter@cousens.her.forthnet.gr