To the people at ProBoard circuits: I am glad to see that you have made some considerable enhancements to the design of your 24-input logic analyzer. As someone who purchased one of the earlier units without said enhancements and found their lacking to have rendered the unit nearly useless to most of my purposes, what would I have to do to upgrade the unit? Also, w/rt your remark that for "real-time" monitoring a scope would be better, I personally would still like to have the ability to see within one video frame any changes on the analyzers' inputs; this should be fairly to implement: simply clock one sample into each FIFO and then spit out the read values [should take almost no time at 115,200 or even 9600].